1  // SPDX-License-Identifier: GPL-2.0
2  /*
3   * Copyright (C) 2006 Matthew Wilcox <matthew@wil.cx>
4   * Copyright (C) 2006-2009 Hewlett-Packard Development Company, L.P.
5   *	Alex Chiang <achiang@hp.com>
6   */
7  
8  #include <linux/kobject.h>
9  #include <linux/slab.h>
10  #include <linux/module.h>
11  #include <linux/pci.h>
12  #include <linux/err.h>
13  #include "pci.h"
14  
15  struct kset *pci_slots_kset;
16  EXPORT_SYMBOL_GPL(pci_slots_kset);
17  
pci_slot_attr_show(struct kobject * kobj,struct attribute * attr,char * buf)18  static ssize_t pci_slot_attr_show(struct kobject *kobj,
19  					struct attribute *attr, char *buf)
20  {
21  	struct pci_slot *slot = to_pci_slot(kobj);
22  	struct pci_slot_attribute *attribute = to_pci_slot_attr(attr);
23  	return attribute->show ? attribute->show(slot, buf) : -EIO;
24  }
25  
pci_slot_attr_store(struct kobject * kobj,struct attribute * attr,const char * buf,size_t len)26  static ssize_t pci_slot_attr_store(struct kobject *kobj,
27  			struct attribute *attr, const char *buf, size_t len)
28  {
29  	struct pci_slot *slot = to_pci_slot(kobj);
30  	struct pci_slot_attribute *attribute = to_pci_slot_attr(attr);
31  	return attribute->store ? attribute->store(slot, buf, len) : -EIO;
32  }
33  
34  static const struct sysfs_ops pci_slot_sysfs_ops = {
35  	.show = pci_slot_attr_show,
36  	.store = pci_slot_attr_store,
37  };
38  
address_read_file(struct pci_slot * slot,char * buf)39  static ssize_t address_read_file(struct pci_slot *slot, char *buf)
40  {
41  	if (slot->number == 0xff)
42  		return sysfs_emit(buf, "%04x:%02x\n",
43  				  pci_domain_nr(slot->bus),
44  				  slot->bus->number);
45  
46  	return sysfs_emit(buf, "%04x:%02x:%02x\n",
47  			  pci_domain_nr(slot->bus),
48  			  slot->bus->number,
49  			  slot->number);
50  }
51  
bus_speed_read(enum pci_bus_speed speed,char * buf)52  static ssize_t bus_speed_read(enum pci_bus_speed speed, char *buf)
53  {
54  	return sysfs_emit(buf, "%s\n", pci_speed_string(speed));
55  }
56  
max_speed_read_file(struct pci_slot * slot,char * buf)57  static ssize_t max_speed_read_file(struct pci_slot *slot, char *buf)
58  {
59  	return bus_speed_read(slot->bus->max_bus_speed, buf);
60  }
61  
cur_speed_read_file(struct pci_slot * slot,char * buf)62  static ssize_t cur_speed_read_file(struct pci_slot *slot, char *buf)
63  {
64  	return bus_speed_read(slot->bus->cur_bus_speed, buf);
65  }
66  
pci_slot_release(struct kobject * kobj)67  static void pci_slot_release(struct kobject *kobj)
68  {
69  	struct pci_dev *dev;
70  	struct pci_slot *slot = to_pci_slot(kobj);
71  
72  	dev_dbg(&slot->bus->dev, "dev %02x, released physical slot %s\n",
73  		slot->number, pci_slot_name(slot));
74  
75  	down_read(&pci_bus_sem);
76  	list_for_each_entry(dev, &slot->bus->devices, bus_list)
77  		if (PCI_SLOT(dev->devfn) == slot->number)
78  			dev->slot = NULL;
79  	up_read(&pci_bus_sem);
80  
81  	list_del(&slot->list);
82  
83  	kfree(slot);
84  }
85  
86  static struct pci_slot_attribute pci_slot_attr_address =
87  	__ATTR(address, S_IRUGO, address_read_file, NULL);
88  static struct pci_slot_attribute pci_slot_attr_max_speed =
89  	__ATTR(max_bus_speed, S_IRUGO, max_speed_read_file, NULL);
90  static struct pci_slot_attribute pci_slot_attr_cur_speed =
91  	__ATTR(cur_bus_speed, S_IRUGO, cur_speed_read_file, NULL);
92  
93  static struct attribute *pci_slot_default_attrs[] = {
94  	&pci_slot_attr_address.attr,
95  	&pci_slot_attr_max_speed.attr,
96  	&pci_slot_attr_cur_speed.attr,
97  	NULL,
98  };
99  ATTRIBUTE_GROUPS(pci_slot_default);
100  
101  static const struct kobj_type pci_slot_ktype = {
102  	.sysfs_ops = &pci_slot_sysfs_ops,
103  	.release = &pci_slot_release,
104  	.default_groups = pci_slot_default_groups,
105  };
106  
make_slot_name(const char * name)107  static char *make_slot_name(const char *name)
108  {
109  	char *new_name;
110  	int len, max, dup;
111  
112  	new_name = kstrdup(name, GFP_KERNEL);
113  	if (!new_name)
114  		return NULL;
115  
116  	/*
117  	 * Make sure we hit the realloc case the first time through the
118  	 * loop.  'len' will be strlen(name) + 3 at that point which is
119  	 * enough space for "name-X" and the trailing NUL.
120  	 */
121  	len = strlen(name) + 2;
122  	max = 1;
123  	dup = 1;
124  
125  	for (;;) {
126  		struct kobject *dup_slot;
127  		dup_slot = kset_find_obj(pci_slots_kset, new_name);
128  		if (!dup_slot)
129  			break;
130  		kobject_put(dup_slot);
131  		if (dup == max) {
132  			len++;
133  			max *= 10;
134  			kfree(new_name);
135  			new_name = kmalloc(len, GFP_KERNEL);
136  			if (!new_name)
137  				break;
138  		}
139  		sprintf(new_name, "%s-%d", name, dup++);
140  	}
141  
142  	return new_name;
143  }
144  
rename_slot(struct pci_slot * slot,const char * name)145  static int rename_slot(struct pci_slot *slot, const char *name)
146  {
147  	int result = 0;
148  	char *slot_name;
149  
150  	if (strcmp(pci_slot_name(slot), name) == 0)
151  		return result;
152  
153  	slot_name = make_slot_name(name);
154  	if (!slot_name)
155  		return -ENOMEM;
156  
157  	result = kobject_rename(&slot->kobj, slot_name);
158  	kfree(slot_name);
159  
160  	return result;
161  }
162  
pci_dev_assign_slot(struct pci_dev * dev)163  void pci_dev_assign_slot(struct pci_dev *dev)
164  {
165  	struct pci_slot *slot;
166  
167  	mutex_lock(&pci_slot_mutex);
168  	list_for_each_entry(slot, &dev->bus->slots, list)
169  		if (PCI_SLOT(dev->devfn) == slot->number)
170  			dev->slot = slot;
171  	mutex_unlock(&pci_slot_mutex);
172  }
173  
get_slot(struct pci_bus * parent,int slot_nr)174  static struct pci_slot *get_slot(struct pci_bus *parent, int slot_nr)
175  {
176  	struct pci_slot *slot;
177  
178  	/* We already hold pci_slot_mutex */
179  	list_for_each_entry(slot, &parent->slots, list)
180  		if (slot->number == slot_nr) {
181  			kobject_get(&slot->kobj);
182  			return slot;
183  		}
184  
185  	return NULL;
186  }
187  
188  /**
189   * pci_create_slot - create or increment refcount for physical PCI slot
190   * @parent: struct pci_bus of parent bridge
191   * @slot_nr: PCI_SLOT(pci_dev->devfn) or -1 for placeholder
192   * @name: user visible string presented in /sys/bus/pci/slots/<name>
193   * @hotplug: set if caller is hotplug driver, NULL otherwise
194   *
195   * PCI slots have first class attributes such as address, speed, width,
196   * and a &struct pci_slot is used to manage them. This interface will
197   * either return a new &struct pci_slot to the caller, or if the pci_slot
198   * already exists, its refcount will be incremented.
199   *
200   * Slots are uniquely identified by a @pci_bus, @slot_nr tuple.
201   *
202   * There are known platforms with broken firmware that assign the same
203   * name to multiple slots. Workaround these broken platforms by renaming
204   * the slots on behalf of the caller. If firmware assigns name N to
205   * multiple slots:
206   *
207   * The first slot is assigned N
208   * The second slot is assigned N-1
209   * The third slot is assigned N-2
210   * etc.
211   *
212   * Placeholder slots:
213   * In most cases, @pci_bus, @slot_nr will be sufficient to uniquely identify
214   * a slot. There is one notable exception - pSeries (rpaphp), where the
215   * @slot_nr cannot be determined until a device is actually inserted into
216   * the slot. In this scenario, the caller may pass -1 for @slot_nr.
217   *
218   * The following semantics are imposed when the caller passes @slot_nr ==
219   * -1. First, we no longer check for an existing %struct pci_slot, as there
220   * may be many slots with @slot_nr of -1.  The other change in semantics is
221   * user-visible, which is the 'address' parameter presented in sysfs will
222   * consist solely of a dddd:bb tuple, where dddd is the PCI domain of the
223   * %struct pci_bus and bb is the bus number. In other words, the devfn of
224   * the 'placeholder' slot will not be displayed.
225   */
pci_create_slot(struct pci_bus * parent,int slot_nr,const char * name,struct hotplug_slot * hotplug)226  struct pci_slot *pci_create_slot(struct pci_bus *parent, int slot_nr,
227  				 const char *name,
228  				 struct hotplug_slot *hotplug)
229  {
230  	struct pci_dev *dev;
231  	struct pci_slot *slot;
232  	int err = 0;
233  	char *slot_name = NULL;
234  
235  	mutex_lock(&pci_slot_mutex);
236  
237  	if (slot_nr == -1)
238  		goto placeholder;
239  
240  	/*
241  	 * Hotplug drivers are allowed to rename an existing slot,
242  	 * but only if not already claimed.
243  	 */
244  	slot = get_slot(parent, slot_nr);
245  	if (slot) {
246  		if (hotplug) {
247  			if ((err = slot->hotplug ? -EBUSY : 0)
248  			     || (err = rename_slot(slot, name))) {
249  				kobject_put(&slot->kobj);
250  				slot = NULL;
251  				goto err;
252  			}
253  		}
254  		goto out;
255  	}
256  
257  placeholder:
258  	slot = kzalloc(sizeof(*slot), GFP_KERNEL);
259  	if (!slot) {
260  		err = -ENOMEM;
261  		goto err;
262  	}
263  
264  	slot->bus = parent;
265  	slot->number = slot_nr;
266  
267  	slot->kobj.kset = pci_slots_kset;
268  
269  	slot_name = make_slot_name(name);
270  	if (!slot_name) {
271  		err = -ENOMEM;
272  		kfree(slot);
273  		goto err;
274  	}
275  
276  	INIT_LIST_HEAD(&slot->list);
277  	list_add(&slot->list, &parent->slots);
278  
279  	err = kobject_init_and_add(&slot->kobj, &pci_slot_ktype, NULL,
280  				   "%s", slot_name);
281  	if (err) {
282  		kobject_put(&slot->kobj);
283  		goto err;
284  	}
285  
286  	down_read(&pci_bus_sem);
287  	list_for_each_entry(dev, &parent->devices, bus_list)
288  		if (PCI_SLOT(dev->devfn) == slot_nr)
289  			dev->slot = slot;
290  	up_read(&pci_bus_sem);
291  
292  	dev_dbg(&parent->dev, "dev %02x, created physical slot %s\n",
293  		slot_nr, pci_slot_name(slot));
294  
295  out:
296  	kfree(slot_name);
297  	mutex_unlock(&pci_slot_mutex);
298  	return slot;
299  err:
300  	slot = ERR_PTR(err);
301  	goto out;
302  }
303  EXPORT_SYMBOL_GPL(pci_create_slot);
304  
305  /**
306   * pci_destroy_slot - decrement refcount for physical PCI slot
307   * @slot: struct pci_slot to decrement
308   *
309   * %struct pci_slot is refcounted, so destroying them is really easy; we
310   * just call kobject_put on its kobj and let our release methods do the
311   * rest.
312   */
pci_destroy_slot(struct pci_slot * slot)313  void pci_destroy_slot(struct pci_slot *slot)
314  {
315  	dev_dbg(&slot->bus->dev, "dev %02x, dec refcount to %d\n",
316  		slot->number, kref_read(&slot->kobj.kref) - 1);
317  
318  	mutex_lock(&pci_slot_mutex);
319  	kobject_put(&slot->kobj);
320  	mutex_unlock(&pci_slot_mutex);
321  }
322  EXPORT_SYMBOL_GPL(pci_destroy_slot);
323  
324  #if defined(CONFIG_HOTPLUG_PCI) || defined(CONFIG_HOTPLUG_PCI_MODULE)
325  #include <linux/pci_hotplug.h>
326  /**
327   * pci_hp_create_module_link - create symbolic link to hotplug driver module
328   * @pci_slot: struct pci_slot
329   *
330   * Helper function for pci_hotplug_core.c to create symbolic link to
331   * the hotplug driver module.
332   */
pci_hp_create_module_link(struct pci_slot * pci_slot)333  void pci_hp_create_module_link(struct pci_slot *pci_slot)
334  {
335  	struct hotplug_slot *slot = pci_slot->hotplug;
336  	struct kobject *kobj = NULL;
337  	int ret;
338  
339  	if (!slot || !slot->ops)
340  		return;
341  	kobj = kset_find_obj(module_kset, slot->mod_name);
342  	if (!kobj)
343  		return;
344  	ret = sysfs_create_link(&pci_slot->kobj, kobj, "module");
345  	if (ret)
346  		dev_err(&pci_slot->bus->dev, "Error creating sysfs link (%d)\n",
347  			ret);
348  	kobject_put(kobj);
349  }
350  EXPORT_SYMBOL_GPL(pci_hp_create_module_link);
351  
352  /**
353   * pci_hp_remove_module_link - remove symbolic link to the hotplug driver
354   * 	module.
355   * @pci_slot: struct pci_slot
356   *
357   * Helper function for pci_hotplug_core.c to remove symbolic link to
358   * the hotplug driver module.
359   */
pci_hp_remove_module_link(struct pci_slot * pci_slot)360  void pci_hp_remove_module_link(struct pci_slot *pci_slot)
361  {
362  	sysfs_remove_link(&pci_slot->kobj, "module");
363  }
364  EXPORT_SYMBOL_GPL(pci_hp_remove_module_link);
365  #endif
366  
pci_slot_init(void)367  static int pci_slot_init(void)
368  {
369  	struct kset *pci_bus_kset;
370  
371  	pci_bus_kset = bus_get_kset(&pci_bus_type);
372  	pci_slots_kset = kset_create_and_add("slots", NULL,
373  						&pci_bus_kset->kobj);
374  	if (!pci_slots_kset) {
375  		pr_err("PCI: Slot initialization failure\n");
376  		return -ENOMEM;
377  	}
378  	return 0;
379  }
380  
381  subsys_initcall(pci_slot_init);
382