Home
last modified time | relevance | path

Searched refs:accuracy (Results 1 – 25 of 107) sorted by relevance

12345

/linux-6.12.1/arch/x86/math-emu/
DREADME72 based upon getting good accuracy with reasonable speed.
228 The accuracy of the emulator is in almost all cases equal to or better
237 The following table compares the emulator accuracy for the sqrt(),
240 would be 64 bits. The reduced Turbo C accuracy of cos() and tan() for
243 accurate to 64 bits can result in a relative accuracy in cos() of
260 ** The accuracy for exp() and log() is low because the FPU (emulator)
274 consequence, the accuracy of these functions for large arguments has
276 FPU). There is also now no degradation of accuracy for fcos and fptan
278 definition of accuracy has changed slightly from that used for the
303 Prior to version 1.20 of the emulator, the accuracy of the results for
[all …]
/linux-6.12.1/drivers/clk/
Dclk-fixed-rate.c165 u32 accuracy = 0; in _of_fixed_clk_setup() local
171 of_property_read_u32(node, "clock-accuracy", &accuracy); in _of_fixed_clk_setup()
176 0, rate, accuracy); in _of_fixed_clk_setup()
Dkunit_clk_fixed_rate_test.dtso12 clock-accuracy = <TEST_FIXED_ACCURACY>;
/linux-6.12.1/drivers/iio/temperature/
DKconfig23 high accuracy digital temperature measurement system.
68 tristate "MLX90632 contact-less infrared sensor with medical accuracy"
73 MLX90632 contact-less infrared sensor with medical accuracy
80 tristate "MLX90635 contact-less infrared sensor with medical accuracy"
85 MLX90635 contact-less infrared sensor with medical accuracy
/linux-6.12.1/Documentation/hwmon/
Dshtc1.rst58 2. high or low accuracy. High accuracy is used by default and using it is
Dtc74.rst18 and +- 2 degrees centigrade accuracy.
Dsparx5-temp.rst24 The sensor has a range of -40°C to +125°C and an accuracy of +/-5°C.
Dpc87360.rst74 readings more range or accuracy. Usually, users have to learn how it works,
81 slowest accuracy highest
94 * accuracy around 3000 RPM: 3000^2/clock
98 RPM as the lowest acceptable accuracy.
Daspeed-g6-pwm-tach.rst24 The larger divisor, the less rpm accuracy and the less
Dadt7410.rst51 -55°C to +150°C. It has a high accuracy of +/-0.5°C and can be operated at a
65 a better accuracy (0.25°C instead of 0.50°C.)
Dgl518sm.rst47 degrees, with a accuracy of +/-3 degrees.
54 give the readings more range or accuracy. Not all RPM values can
Dlan966x.rst25 its accuracy is +/- 5 degrees Celsius. The fan controller has a
Dmax6620.rst28 range or accuracy, the desired value can be set by a programmable register
Dds620.rst25 to +125. Between 0 and 70 degree Celsius, accuracy is 0.5 Kelvin. The value
/linux-6.12.1/drivers/clk/at91/
Dclk-main.c40 unsigned long accuracy; member
266 return osc->accuracy; in clk_main_rc_osc_recalc_accuracy()
299 u32 frequency, u32 accuracy) in at91_clk_register_main_rc_osc() argument
322 osc->accuracy = accuracy; in at91_clk_register_main_rc_osc()
Dsckc.c53 unsigned long accuracy; member
183 return osc->accuracy; in clk_slow_rc_osc_recalc_accuracy()
228 unsigned long accuracy, in at91_clk_register_slow_rc_osc() argument
254 osc->accuracy = accuracy; in at91_clk_register_slow_rc_osc()
/linux-6.12.1/Documentation/ABI/testing/
Dsysfs-bus-iio-adc-mt636012 Indicated MT6360 VBUS ADC with lower accuracy(+-75mA)
20 Indicated MT6360 VBUS ADC with higher accuracy(+-30mA)
Dsysfs-bus-iio-light-tsl258320 It is used in the process of calibrating the device accuracy.
/linux-6.12.1/arch/arm/boot/dts/alphascale/
Dalphascale-asm9260.dtsi34 clock-accuracy = <30000>;
/linux-6.12.1/Documentation/devicetree/bindings/mtd/
Dlpc32xx-mlc.txt12 accuracy:)
/linux-6.12.1/arch/arm/boot/dts/intel/pxa/
Dpxa300-raumfeld-tuneable-clock.dtsi10 clock-accuracy = <100>;
/linux-6.12.1/drivers/gpu/drm/ci/xfails/
Di915-kbl-fails.txt17 perf_pmu@busy-accuracy-50,Fail
/linux-6.12.1/drivers/hid/amd-sfh-hid/sfh1_1/
Damd_sfh_interface.h143 u32 accuracy; member
/linux-6.12.1/Documentation/timers/
Dtimekeeping.rst46 When the wall-clock accuracy of the clock source isn't satisfactory, there
125 between accuracy compared to the clock source, you may sacrifice accuracy
135 jiffy frequency for the architecture. This will affect scheduling accuracy
/linux-6.12.1/Documentation/sound/designs/
Dtimestamping.rst76 accuracy. It can also request the delay-to-analog be included in the
92 The audio timestamp accuracy can be returned to user-space, so that
115 The accuracy is reported in nanosecond units (using an unsigned 32-bit
191 shows how compensating for the delay exposes a 1ms accuracy (due to

12345