/linux-6.12.1/Documentation/translations/zh_CN/PCI/ |
D | pci-iov-howto.rst | 32 虚拟设备。物理设备被称为物理功能(PF),而虚拟设备被称为虚拟功能(VF)。VF的分 34 现为传统的PCIe设备。一旦开启,每个VF的PCI配置空间都可以通过自己的总线、设备和 35 功能编号(路由ID)来访问。而且每个VF也有PCI内存空间,用于映射其寄存器集。VF设 47 用它和与PF相关的所有VF。一些PF驱动需要设置一个模块参数,以确定要启用的VF的数量。 48 在第二种方法中,对sysfs文件sriov_numvfs的写入将启用和禁用与PCIe PF相关的VF。 49 这种方法实现了每个PF的VF启用/禁用值,而第一种方法则适用于同一设备的所有PF。此外, 51 复,例如,如果启用VF,检查numvfs == 0,确保numvfs <= totalvfs。 52 第二种方法是对新的/未来的VF设备的推荐方法。 57 在内核中,VF被视为热插拔的PCI设备,所以它们应该能够以与真正的PCI设备相同的方式 58 工作。VF需要的设备驱动与普通PCI设备的驱动相同。 [all …]
|
/linux-6.12.1/Documentation/arch/powerpc/ |
D | pci_iov_resource_on_powernv.rst | 170 PCI devices, but the BARs in VF config space headers are unusual. For 171 a non-VF device, software uses BARs in the config space header to 172 discover the BAR sizes and assign addresses for them. For VF devices, 173 software uses VF BAR registers in the *PF* SR-IOV Capability to 174 discover sizes and assign addresses. The BARs in the VF's config space 177 When a VF BAR in the PF SR-IOV Capability is programmed, it sets the 178 base address for all the corresponding VF(n) BARs. For example, if the 180 1MB VF BAR0, the address in that VF BAR sets the base of an 8MB region. 182 is a BAR0 for one of the VFs. Note that even though the VF BAR 183 describes an 8MB region, the alignment requirement is for a single VF, [all …]
|
/linux-6.12.1/Documentation/networking/ |
D | net_failover.rst | 25 direct attached VF by failing over to the paravirtual datapath when the VF 36 virtio-net and VF interfaces. 64 the VF passthrough device for normal communication. The virtio-net device will 67 The second device definition is for the VF passthrough interface. Here the 88 virtio-net interface, and ens11 is the slave 'primary' VF passthrough interface. 93 and VF acquiring IP addresses (either same or different) from the DHCP server. 113 Live Migration of a VM with SR-IOV VF & virtio-net in STANDBY mode 117 with VMs that have direct attached SR-IOV VF devices by automatic failover to 118 the paravirtual datapath when the VF is unplugged. 122 software bridge 'br0' which has a single VF attached to it along with the vnet [all …]
|
D | representors.rst | 47 these administrative privileges instead to a VF or SF (subfunction). 57 the case of a VF representor, the representee is the corresponding VF. 82 on a VF representor applies in software to packets received on that representor 84 the representee VF. Conversely, a mirred egress redirect to a VF representor 85 corresponds in hardware to delivery directly to the representee VF. 112 PF or VF. 119 correspondence between VF netdevices and VF representors, more advanced device 197 ``REP_DEV`` is a VF representor, the following rules:: 204 would mean that all IPv4 packets from the VF are sent out the physical port, and 205 all IPv4 packets received on the physical port are delivered to the VF in [all …]
|
D | failover.rst | 16 This enables paravirtual drivers to use a VF as an accelerated low latency 18 failing over to the paravirtual datapath when the VF is unplugged.
|
/linux-6.12.1/Documentation/misc-devices/ |
D | mrvl_cn10k_dpi.rst | 15 requests from its VF functions and provisions DMA engine resources to 16 it's VF functions. 19 mailbox commands submitted by the VF devices and accordingly initializes 20 the DMA engines and VF device's DMA command queues. Also, driver creates 24 DPI PF driver is just an administrative driver to setup its VF device's 26 DMA operations. Only VF devices are provisioned with DMA capabilities. 48 DPI VF devices are probed and accessed from user space applications using
|
/linux-6.12.1/Documentation/ABI/testing/ |
D | debugfs-hisi-hpre | 33 Description: The <bdf> is related the function for PF and VF. 50 Available for PF and VF in host. VF in guest currently only 74 Available for both PF and VF, and take no other effect on HPRE. 80 Available for both PF and VF, and take no other effect on HPRE. 86 Available for both PF and VF, and take no other effect on HPRE. 92 Available for both PF and VF, and take no other effect on HPRE. 98 Available for both PF and VF, and take no other effect on HPRE. 105 Available for both PF and VF, and take no other effect on HPRE. 125 and VF, and take no other effect on HPRE. 133 will return non-zero value. Available for both PF and VF, [all …]
|
D | debugfs-hisi-sec | 20 Description: The <bdf> is related the function for PF and VF. 31 Available for PF and VF in host. VF in guest currently only 54 Available for both PF and VF, and take no other effect on SEC. 60 Available for both PF and VF, and take no other effect on SEC. 66 Available for both PF and VF, and take no other effect on SEC. 72 Available for both PF and VF, and take no other effect on SEC. 78 Available for both PF and VF, and take no other effect on SEC. 85 Available for both PF and VF, and take no other effect on SEC. 105 and VF, and take no other effect on SEC. 113 will return non-zero value. Available for both PF and VF, [all …]
|
D | debugfs-hisi-zip | 32 Description: The <bdf> is related the function for PF and VF. 43 Available for PF and VF in host. VF in guest currently only 67 Available for both PF and VF, and take no other effect on ZIP. 73 Available for both PF and VF, and take no other effect on ZIP. 79 Available for both PF and VF, and take no other effect on ZIP. 85 Available for both PF and VF, and take no other effect on ZIP. 91 Available for both PF and VF, and take no other effect on ZIP. 98 Available for both PF and VF, and take no other effect on ZIP. 118 and VF, and take no other effect on ZIP. 126 will return non-zero value. Available for both PF and VF, [all …]
|
/linux-6.12.1/Documentation/networking/devlink/ |
D | devlink-port.rst | 36 virtual function (VF). 145 The configured MAC address of the PCI VF/SF will be used by netdevice and rdma 146 device created for the PCI VF/SF. 148 - Get the MAC address of the VF identified by its unique devlink port index:: 155 - Set the MAC address of the VF identified by its unique devlink port index:: 184 When RoCE capability is disabled, it saves system memory per PCI VF/SF. 186 When user disables RoCE capability for a VF/SF, user application cannot send or 187 receive any RoCE packets through this VF/SF and RoCE GID table for this PCI 191 VF/SF driver cannot override it. 193 - Get RoCE capability of the VF device:: [all …]
|
D | octeontx2.rst | 7 This document describes the devlink features implemented by the ``octeontx2 AF, PF and VF`` 13 The ``octeontx2 PF and VF`` drivers implement the following driver-specific parameters. 27 PF and VF drivers.
|
/linux-6.12.1/Documentation/networking/device_drivers/ethernet/amd/ |
D | pds_vfio_pci.rst | 15 capable Virtual Function (VF) devices in the DSC hardware. 24 Shown below are the steps to bind the driver to a VF and also to the 38 # Prevent non-vfio VF driver from probing the VF device 41 # Create single VF for Live Migration via pds_core 44 # Allow the VF to be bound to the pds-vfio-pci driver 47 # Bind the VF to the pds-vfio-pci driver
|
D | pds_vdpa.rst | 8 AMD/Pensando vDPA VF Device Driver 19 and VF PCI handling as well as for device configuration services. 41 # Enable vDPA VF auxiliary device(s) in the PF 44 # Create a VF for vDPA use
|
/linux-6.12.1/Documentation/networking/device_drivers/ethernet/intel/ |
D | iavf.rst | 73 packets with VLAN tags, you can disable VLAN tag stripping for the VF. The 74 Physical Function (PF) processes requests issued from the VF to enable or 75 disable VLAN tag stripping. Note that if the PF has assigned a VLAN to a VF, 76 then requests from that VF to set VLAN tag stripping will be ignored. 78 To enable/disable VLAN tag stripping for a VF, issue the following command 79 from inside the VM in which you are running the VF:: 89 Adaptive Virtual Function (AVF) allows the virtual function driver, or VF, to 106 - 1 Virtual Station Interface (VSI) per VF 110 - 1 unicast MAC address reserved per VF 111 - 16 MAC address filters for each VF [all …]
|
D | ice.rst | 20 The associated Virtual Function (VF) driver for this driver is iavf. 66 support SR-IOV, the virtual function (VF) may be subject to malicious behavior. 79 Do not unload port driver if VF with active VM is bound to it 81 Do not unload a port's driver if a Virtual Function (VF) with an active Virtual 83 Once the VM shuts down, or otherwise releases the VF, the command will 479 Use sysfs to enable virtual functions (VF). 498 Displaying VF Statistics on the PF 515 following command. The VLAN configuration should be done before the VF driver 516 is loaded or the VM is booted. The VF is not aware of the VLAN tag being 524 For example, the following will configure PF eth0 and the first VF on VLAN 10:: [all …]
|
D | i40e.rst | 70 For example, the following instructions will configure PF eth0 and the first VF 78 virtual function (VF). Further, this feature allows you to designate a 79 particular VF as trusted, and allows that trusted VF to request selective 82 To set a VF as trusted or untrusted, enter the following command in the 87 Once the VF is designated as trusted, use the following commands in the VM to 88 set the VF to promiscuous mode. 94 Where eth2 is a VF interface in the VM 98 Where eth2 is a VF interface in the VM 101 "off",meaning that promiscuous mode for the VF will be limited. To set the 102 promiscuous mode for the VF to true promiscuous and allow the VF to see all [all …]
|
/linux-6.12.1/Documentation/PCI/ |
D | pci-iov-howto.rst | 21 while the virtual devices are referred to as Virtual Functions (VF). 22 Allocation of the VF can be dynamically controlled by the PF via 25 turned on, each VF's PCI configuration space can be accessed by its own 26 Bus, Device and Function Number (Routing ID). And each VF also has PCI 27 Memory Space, which is used to map its register set. VF device driver 45 enables per-PF, VF enable/disable values versus the first method, 51 The second method is the recommended method for new/future VF devices. 56 The VF is treated as hot-plugged PCI devices in the kernel, so they 57 should be able to work in the same way as real PCI devices. The VF
|
/linux-6.12.1/drivers/net/ethernet/marvell/octeon_ep_vf/ |
D | Kconfig | 3 # Marvell's Octeon PCI Endpoint NIC VF Driver Configuration 7 tristate "Marvell Octeon PCI Endpoint NIC VF Driver" 12 Octeon PCI Endpoint NIC VF.
|
/linux-6.12.1/Documentation/networking/device_drivers/ethernet/marvell/ |
D | octeon_ep_vf.rst | 4 Linux kernel networking driver for Marvell's Octeon PCI Endpoint NIC VF 7 Network driver for Marvell's Octeon PCI EndPoint NIC VF. 13 EndPoint NIC VF.
|
D | octeontx2.rst | 28 PF/VF. 44 - A PF/VF with NIX-LF & NPA-LF resources works as a pure network device 45 - A PF/VF with CPT-LF resource works as a pure crypto offload device. 86 - Attach NIX and NPA block LFs to RVU PF/VF which provide buffer pools, RQs, SQs 123 the reply to VF. 124 - From functionality point of view there is no difference between PF and VF as same type 138 no other difference between these VF types. AF driver takes care of IO channel mapping, 139 hence same VF driver works for both types of devices.
|
/linux-6.12.1/Documentation/networking/device_drivers/ethernet/microsoft/ |
D | netvsc.rst | 71 Virtual Function (VF) device is passed to the guest as a PCI 72 device. In this case, both a synthetic (netvsc) and VF device are 75 The VF is enslaved by netvsc device. The netvsc driver will transparently 76 switch the data path to the VF when it is available and up. 81 VF slave device. 108 program on the associated VF NIC as well. 111 VF NIC automatically. Setting / unsetting XDP program on VF NIC directly
|
/linux-6.12.1/Documentation/admin-guide/perf/ |
D | hns3-pmu.rst | 106 PMU collect performance statistic of one PF/VF. The function id is BDF of 107 PF/VF, its conversion formula:: 123 PMU collect performance statistic of one queue of PF/VF. The function id 124 is BDF of PF/VF, the "queue" filter option must be set to the exact queue 131 PMU collect performance statistic of one interrupt of PF/VF. The function 132 id is BDF of PF/VF, the "intr" filter option must be set to the exact
|
/linux-6.12.1/drivers/vfio/pci/virtio/ |
D | Kconfig | 7 This provides support for exposing VIRTIO NET VF devices which support 11 As of that this driver emulates I/O BAR in software to let a VF be
|
/linux-6.12.1/Documentation/networking/device_drivers/ethernet/mellanox/mlx5/ |
D | switchdev.rst | 160 The mlx5 driver provides a mechanism to setup PCI VF/SF function attributes in 164 configuration of the PCI VF/SF is supported through devlink eswitch port. 166 Port function attributes should be set before PCI VF/SF is enumerated by the 188 explicitly enable the VF migratable capability. 196 to explicitly enable the VF ipsec_crypto capability. Enabling IPsec capability 197 for VFs is supported starting with ConnectX6dx devices and above. When a VF has 206 to explicitly enable the VF ipsec_packet capability. Enabling IPsec capability 207 for VFs is supported starting with ConnectX6dx devices and above. When a VF has
|
/linux-6.12.1/drivers/net/ethernet/freescale/enetc/ |
D | Kconfig | 5 This module supports common functionality between the PF and VF 28 tristate "ENETC VF driver" 36 virtual function (VF) devices enabled by the ENETC PF driver.
|