Lines Matching +full:counter +full:- +full:2
3 …with all the following traits: 1. addressing of the format [base + offset], 2. the offset is betwe…
4 "Counter": "0,1,2,3", string
12 "Counter": "0,1,2,3", string
23 "Counter": "0,1,2,3", string
31 "Counter": "0,1,2,3", string
38 "BriefDescription": "Speculative and retired macro-conditional branches.",
39 "Counter": "0,1,2,3", string
46 …"BriefDescription": "Speculative and retired macro-unconditional branches excluding calls and indi…
47 "Counter": "0,1,2,3", string
55 "Counter": "0,1,2,3", string
63 "Counter": "0,1,2,3", string
71 "Counter": "0,1,2,3", string
78 "BriefDescription": "Not taken macro-conditional branches.",
79 "Counter": "0,1,2,3", string
86 "BriefDescription": "Taken speculative and retired macro-conditional branches.",
87 "Counter": "0,1,2,3", string
94 …"BriefDescription": "Taken speculative and retired macro-conditional branch instructions excluding…
95 "Counter": "0,1,2,3", string
103 "Counter": "0,1,2,3", string
111 "Counter": "0,1,2,3", string
119 "Counter": "0,1,2,3", string
127 "Counter": "0,1,2,3", string
135 "Counter": "0,1,2,3", string
141 "BriefDescription": "All (macro) branch instructions retired. (Precise Event - PEBS).",
142 "Counter": "0,1,2,3", string
145 "PEBS": "2",
151 "Counter": "0,1,2,3", string
160 "Counter": "0,1,2,3", string
168 "Counter": "0,1,2,3", string
177 "Counter": "0,1,2,3", string
186 "Counter": "0,1,2,3", string
195 "Counter": "0,1,2,3", string
203 "Counter": "0,1,2,3", string
211 "Counter": "0,1,2,3", string
219 "Counter": "0,1,2,3", string
227 "Counter": "0,1,2,3", string
235 "Counter": "0,1,2,3", string
238 …"PublicDescription": "Counts speculatively miss-predicted indirect branches at execution time. Cou…
244 "Counter": "0,1,2,3", string
252 "Counter": "0,1,2,3", string
260 "Counter": "0,1,2,3", string
268 "Counter": "0,1,2,3", string
276 "Counter": "0,1,2,3", string
284 "Counter": "0,1,2,3", string
292 "Counter": "0,1,2,3", string
298 … "BriefDescription": "Mispredicted macro branch instructions retired. (Precise Event - PEBS).",
299 "Counter": "0,1,2,3", string
302 "PEBS": "2",
308 "Counter": "0,1,2,3", string
317 "Counter": "0,1,2,3", string
326 "Counter": "0,1,2,3", string
335 "Counter": "0,1,2,3", string
344 "Counter": "0,1,2,3", string
352 "Counter": "0,1,2,3", string
361 "Counter": "0,1,2,3", string
369 "Counter": "0,1,2,3", string
377 "Counter": "Fixed counter 2", string
379 …counter. This event can approximate elapsed time while the core was not in a halt state. This even…
385 "Counter": "0,1,2,3", string
394 "Counter": "0,1,2,3", string
402 "Counter": "Fixed counter 1", string
404 …e the core was not in the halt state. It is counted on a dedicated fixed counter, leaving the four…
411 "Counter": "Fixed counter 2", string
418 "Counter": "0,1,2,3", string
426 "Counter": "0,1,2,3", string
432 …miss-pending demand load this thread, increment by 1. Note this is in DCU and connected to Umask 1…
433 "Counter": "2", string
434 "CounterMask": "2",
441 …"BriefDescription": "Each cycle there was a MLC-miss pending demand load this thread (i.e. Non-com…
442 "Counter": "0,1,2,3", string
450 … no dispatch for this thread, increment by 1. Note this is connect to Umask 2. No dispatch can be …
451 "Counter": "0,1,2,3", string
459 …-pending demand load this thread and no uops dispatched, increment by 1. Note this is in DCU and c…
460 "Counter": "2", string
468 …-miss pending demand load and no uops dispatched on this thread (i.e. Non-completed valid SQ entry…
469 "Counter": "0,1,2,3", string
478 "Counter": "0,1,2,3", string
486 "Counter": "0,1,2,3", string
494 "Counter": "Fixed counter 0", string
496 … For instructions that consist of multiple micro-ops, this event counts the retirement of the last…
501 … "BriefDescription": "Number of instructions retired. General Counter - architectural event.",
502 "Counter": "0,1,2,3", string
508 "BriefDescription": "Instructions retired. (Precise Event - PEBS).",
509 "Counter": "1", string
512 "PEBS": "2",
518 "Counter": "0,1,2,3", string
526 "Counter": "0,1,2,3", string
536 "Counter": "0,1,2,3", string
545 "Counter": "0,1,2,3", string
554 …"BriefDescription": "Number of cases where any load ends up with a valid block-code written to the…
555 "Counter": "0,1,2,3", string
563 "Counter": "0,1,2,3", string
571 "Counter": "0,1,2,3", string
578 …"BriefDescription": "Cases when loads get true Block-on-Store blocking code preventing store forwa…
579 "Counter": "0,1,2,3", string
582 …tore. See the table of not supported store forwards in the Intel? 64 and IA-32 Architectures Opti…
588 "Counter": "0,1,2,3", string
597 "Counter": "0,1,2,3", string
604 …"BriefDescription": "Not software-prefetch load dispatches that hit FB allocated for hardware pref…
605 "Counter": "0,1,2,3", string
612 …"BriefDescription": "Not software-prefetch load dispatches that hit FB allocated for software pref…
613 "Counter": "0,1,2,3", string
621 "Counter": "0,1,2,3", string
630 "Counter": "0,1,2,3", string
639 "Counter": "0,1,2,3", string
647 "Counter": "0,1,2,3", string
657 "Counter": "0,1,2,3", string
660 …"PublicDescription": "Maskmov false fault - counts number of time ucode passes through Maskmov flo…
665 "BriefDescription": "Self-modifying code (SMC) detected.",
666 "Counter": "0,1,2,3", string
669 …"PublicDescription": "This event is incremented when self-modifying code (SMC) is detected, which …
675 "Counter": "0,1,2,3", string
682 "BriefDescription": "Increments the number of flags-merge uops in flight each cycle.",
683 "Counter": "0,1,2,3", string
690 … "BriefDescription": "Performance sensitive flags-merging uops added by Sandy Bridge u-arch.",
691 "Counter": "0,1,2,3", string
695 …cuting performance-sensitive flags-merging uops. For example, shift CL (merge_arith_flags). For mo…
701 "Counter": "0,1,2,3", string
709 "Counter": "0,1,2,3", string
712 … where base is EBR/RBP/R13, using RIP relative or 16-bit addressing modes. See the Intel? 64 and I…
717 "BriefDescription": "Resource-related stall cycles.",
718 "Counter": "0,1,2,3", string
726 "Counter": "0,1,2,3", string
734 "Counter": "0,1,2,3", string
742 "Counter": "0,1,2,3", string
750 "Counter": "0,1,2,3", string
757 "BriefDescription": "Cycles stalled due to re-order buffer full.",
758 "Counter": "0,1,2,3", string
766 "Counter": "0,1,2,3", string
774 "Counter": "0,1,2,3", string
782 "Counter": "0,1,2,3", string
790 "Counter": "0,1,2,3", string
798 "Counter": "0,1,2,3", string
806 "Counter": "0,1,2,3", string
814 "Counter": "0,1,2,3", string
822 "Counter": "0,1,2,3", string
830 "Counter": "0,1,2,3", string
841 "Counter": "0,1,2,3", string
849 "Counter": "0,1,2,3", string
857 "Counter": "0,1,2,3", string
866 "Counter": "0,1,2,3", string
874 "Counter": "0,1,2,3", string
883 "Counter": "0,1,2,3", string
890 "BriefDescription": "Cycles per thread when load or STA uops are dispatched to port 2.",
891 "Counter": "0,1,2,3", string
899 "BriefDescription": "Cycles per core when load or STA uops are dispatched to port 2.",
900 "Counter": "0,1,2,3", string
908 "Counter": "0,1,2,3", string
917 "Counter": "0,1,2,3", string
925 "Counter": "0,1,2,3", string
934 "Counter": "0,1,2,3", string
942 "Counter": "0,1,2,3", string
951 "Counter": "0,1,2,3", string
958 … "BriefDescription": "Cycles at least 1 micro-op is executed from any thread on physical core.",
959 "Counter": "0,1,2,3", string
967 … "BriefDescription": "Cycles at least 2 micro-op is executed from any thread on physical core.",
968 "Counter": "0,1,2,3", string
969 "CounterMask": "2",
976 … "BriefDescription": "Cycles at least 3 micro-op is executed from any thread on physical core.",
977 "Counter": "0,1,2,3", string
985 … "BriefDescription": "Cycles at least 4 micro-op is executed from any thread on physical core.",
986 "Counter": "0,1,2,3", string
994 "BriefDescription": "Cycles with no micro-ops executed from any thread on physical core.",
995 "Counter": "0,1,2,3", string
1004 "Counter": "0,1,2,3", string
1007 …": "This event counts the number of Uops issued by the front-end of the pipeilne to the back-end.",
1014 "Counter": "0,1,2,3", string
1024 "Counter": "0,1,2,3", string
1034 "Counter": "0,1,2,3", string
1038 "PublicDescription": "This event counts the number of micro-ops retired.",
1044 "Counter": "0,1,2,3", string
1054 "Counter": "0,1,2,3", string
1058 …h cycle - meaning, 4 micro-ops or 4 instructions could retire each cycle. This event is used in d…
1064 "Counter": "0,1,2,3", string
1074 "Counter": "0,1,2,3", string