Lines Matching full:load
5 …p (prediction=correct) for all data types excluding data prefetch (demand load,inst prefetch,inst …
6 …this scope was chip pump (prediction=correct) for all data types ( demand load,data,inst prefetch,…
11 …fDescription": "Initial and Final Pump Scope was chip pump (prediction=correct) for a demand load",
12 …Pump Scope and data sourced across this scope was chip pump (prediction=correct) for a demand load"
17 … was reloaded from another chip's memory on the same Node or Group (Distant) due to a demand load",
23 …tion": "The processor's data cache was reloaded from the local chip's Memory due to a demand load",
29 …as reloaded from a memory location including L4 from local remote or distant due to a demand load",
35 …ache was reloaded from another chip's L4 on the same Node or Group ( Remote) due to a demand load",
41 … was reloaded from another chip's memory on the same Node or Group ( Remote) due to a demand load",
47 …Description": "Initial and Final Pump Scope was group pump (prediction=correct) for a demand load",
48 … "Initial and Final Pump Scope and data sourced across this scope was group pump for a demand load"
53 …al Pump Scope (Group) ended up either larger or smaller than Initial Pump Scope for a demand load",
59 …tion": "Final Pump Scope (Group) ended up larger than Initial Pump Scope (Chip) for a demand load",
60 …nitial Pump Scope (Chip) Final pump was group pump and initial pump was chip pumpfor a demand load"
65 … "BriefDescription": "Pump prediction correct. Counts across all types of pumps for a demand load",
71 "BriefDescription": "Pump misprediction. Counts across all types of pumps for a demand load",
72 "PublicDescription": "Pump Mis prediction Counts across all types of pumpsfor a demand load"
77 …escription": "Initial and Final Pump Scope was system pump (prediction=correct) for a demand load",
78 …"Initial and Final Pump Scope and data sourced across this scope was system pump for a demand load"
83 …Group) or the original scope was System and it should have been smaller. Counts for a demand load",
89 …"Final Pump Scope (system) ended up larger than Initial Pump Scope (Chip/Group) for a demand load",
90 …em) to get data sourced, ended up larger than Initial Pump Scope (Chip or Group) for a demand load"
113 …s scope was group pump for all data types excluding data prefetch (demand load,inst prefetch,inst …
119 …han Initial Pump Scope for all data types excluding data prefetch (demand load,inst prefetch,inst …
125 …tial Pump Scope (Chip) for all data types excluding data prefetch (demand load,inst prefetch,inst …
126 …tial pump was chip pumpfor all data types excluding data prefetch (demand load,inst prefetch,inst …
185 …oss all types of pumps for all data types excluding data prefetch (demand load,inst prefetch,inst …
186 …ross all types of pumpsfor all data types excluding data prefetch (demand load,inst prefetch,inst …
191 …oss all types of pumps for all data types excluding data prefetch (demand load,inst prefetch,inst …
192 …ross all types of pumpsfor all data types excluding data prefetch (demand load,inst prefetch,inst …
197 … Scope was system pump for all data types excluding data prefetch (demand load,inst prefetch,inst …
198 … scope was system pump for all data types excluding data prefetch (demand load,inst prefetch,inst …
203 …e been smaller. Counts for all data types excluding data prefetch (demand load,inst prefetch,inst …
209 …ump Scope (Chip/Group) for all data types excluding data prefetch (demand load,inst prefetch,inst …
210 … Scope (Chip or Group) for all data types excluding data prefetch (demand load,inst prefetch,inst …