Lines Matching +full:0 +full:x49c

33 	[DIAG_STAT_X008] = { .code = 0x008, .name = "Console Function" },
34 [DIAG_STAT_X00C] = { .code = 0x00c, .name = "Pseudo Timer" },
35 [DIAG_STAT_X010] = { .code = 0x010, .name = "Release Pages" },
36 [DIAG_STAT_X014] = { .code = 0x014, .name = "Spool File Services" },
37 [DIAG_STAT_X044] = { .code = 0x044, .name = "Voluntary Timeslice End" },
38 [DIAG_STAT_X064] = { .code = 0x064, .name = "NSS Manipulation" },
39 [DIAG_STAT_X08C] = { .code = 0x08c, .name = "Access 3270 Display Device Information" },
40 [DIAG_STAT_X09C] = { .code = 0x09c, .name = "Relinquish Timeslice" },
41 [DIAG_STAT_X0DC] = { .code = 0x0dc, .name = "Appldata Control" },
42 [DIAG_STAT_X204] = { .code = 0x204, .name = "Logical-CPU Utilization" },
43 [DIAG_STAT_X210] = { .code = 0x210, .name = "Device Information" },
44 [DIAG_STAT_X224] = { .code = 0x224, .name = "EBCDIC-Name Table" },
45 [DIAG_STAT_X250] = { .code = 0x250, .name = "Block I/O" },
46 [DIAG_STAT_X258] = { .code = 0x258, .name = "Page-Reference Services" },
47 [DIAG_STAT_X26C] = { .code = 0x26c, .name = "Certain System Information" },
48 [DIAG_STAT_X288] = { .code = 0x288, .name = "Time Bomb" },
49 [DIAG_STAT_X2C4] = { .code = 0x2c4, .name = "FTP Services" },
50 [DIAG_STAT_X2FC] = { .code = 0x2fc, .name = "Guest Performance Data" },
51 [DIAG_STAT_X304] = { .code = 0x304, .name = "Partition-Resource Service" },
52 [DIAG_STAT_X308] = { .code = 0x308, .name = "List-Directed IPL" },
53 [DIAG_STAT_X318] = { .code = 0x318, .name = "CP Name and Version Codes" },
54 [DIAG_STAT_X320] = { .code = 0x320, .name = "Certificate Store" },
55 [DIAG_STAT_X49C] = { .code = 0x49c, .name = "Warning-Track Interruption" },
56 [DIAG_STAT_X500] = { .code = 0x500, .name = "Virtio Service" },
81 if (n == 0) { in show_diag_stat()
100 return 0; in show_diag_stat()
131 return 0; in show_diag_stat_init()
151 * Diagnose 0c: Pseudo Timer
164 * 0x0: Read the Next Spool File Buffer (Data Record)
165 * 0x28: Position a Spool File to the Designated Record
166 * 0xfff: Retrieve Next File Descriptor
168 * For subcommands 0x0 and 0xfff, the value of the first parameter is
177 case 0x0: in diag14()
178 case 0xfff: in diag14()
196 " diag %[addr],%[rp],0x204\n" in __diag204()
197 "0: nopr %%r7\n" in __diag204()
198 EX_TABLE(0b,0b) in __diag204()
287 " diag %[type],%[addr],0x224\n" in diag224()
288 "0: lhi %[rc],0\n" in diag224()
290 EX_TABLE(0b,1b) in diag224()
293 : [type] "d" (0), [addr] "d" (addr)); in diag224()
314 " diag %[subcode],0,0x49c\n" in diag49c()