Lines Matching +full:20 +full:system
29 1.3 System Requirements
106 1.3. System Requirements
111 * Cirrus Logic LAN (CS8900/20-based) Ethernet ISA Adapter
125 * CS8900/20 Setup Utility (DOS-based)
155 stored in an on-board EEPROM. You must use the DOS-based CS8900/20 Setup
163 Since the CS8900/20 Setup Utility is a DOS-based application, you must install
164 and configure the adapter in a DOS-based system using the CS8900/20 Setup
165 Utility before installation in the target LINUX system. (Not required if
187 CS8900/20 Setup Utility.
196 run the CS8900/20 Setup Utility to disable PnP and configure the
197 adapter before installation in the target Linux system. Failure to do
208 * RUN THE CS8900/20 SETUP UTILITY TO DISABLE PnP SUPPORT AND *
305 In this example we are telling the module system that the
383 the CS8900/20 Setup Utility can be used to test the functionality of the
388 CS8900/20-based adapter card (it must also be running the CS8900/20 Setup
394 DOS-only operating system environment. DO NOT run the diagnostics
396 OS/2, or other operating system.
398 To run the diagnostics tests on the CS8900/20 adapter:
400 1. Boot DOS on the PC and start the CS8900/20 Setup Utility.
414 its ability to communicate across the ISA bus based on the system resources
419 The IO Register Read/Write test insures that the CS8900/20 can be
424 The Shared Memory test insures the CS8900/20 can be accessed in memory
426 with other devices in the system.
439 The Chip RAM test insures the 4K of memory internal to the CS8900/20 is
457 Failure of a test item indicates a possible system resource conflict with
459 option to reconfigure the adapter by selecting a different value for the system
467 transferring data between two CS8900/20 adapters installed in different PCs
471 This test requires that each of the two PCs have a CS8900/20-based adapter
472 installed and have the CS8900/20 Setup Utility running. The first PC is
484 1. Select a PC with a CS8900/20-based adapter and a known working network
485 connection to act as the Responder. Run the CS8900/20 Setup Utility
489 2. Return to the PC with the CS8900/20-based adapter you want to test and
490 start the CS8900/20 Setup Utility.
521 of four ways after installing and or configuring the CS8900/20-based adapter:
523 1. The system does not boot properly (or at all).
534 If an IO conflict occurs, run the CS8900/20 Setup Utility and perform a
542 CS8900/20 Setup Utility. Once reinstalled in the target system, run the
546 When manually configuring the adapter, keep in mind the typical ISA system
553 200-20F Game I/O adapter 3 COM2, Bus Mouse
601 3.) PC System's Configuration
603 * Plug and Play system (yes/no)
605 * System make and model
607 * System RAM
613 * Your network operating system and version
614 * Your system's OS version