Lines Matching +full:no +full:- +full:reset +full:- +full:on +full:- +full:init
10 Addresses scanned: I2C 0x2c - 0x2f
12 Datasheet: http://www.winbond-usa.com/products/winbond_products/pdfs/PCIC/W83791D_W83791Gb.pdf
22 - Frodo Looijaard <frodol@dds.nl>,
23 - Philip Edelbrock <phil@netroedge.com>,
24 - Mark Studebaker <mdsxyz123@yahoo.com>
28 - Shane Huang (Winbond),
29 - Rudolf Marek <r.marek@assembler.cz>
33 - Sven Anders <anders@anduras.de>
34 - Marc Hulsman <m.hulsman@tudelft.nl>
37 -----------------
39 * init boolean
42 Use 'init=1' to have the driver do extra software initializations.
44 and depend on the BIOS to properly setup the chip. If you know you
45 have a w83791d and you're having problems, try init=1 before trying
46 reset=1.
48 * reset boolean
51 Use 'reset=1' to reset the chip (via index 0x40, bit 7). The default
52 behavior is no chip reset to preserve BIOS settings.
57 to force the subclients of chip 0x2f on bus 0 to i2c addresses
62 -----------
68 internal state that allows no clean access (Bank with ID register is not
70 parameter; this will put it into a more well-behaved state first.
78 on until the temperature falls below the Hysteresis value.
91 PWM 1-3 support Thermal Cruise mode, in which the PWMs are automatically
92 regulated to keep respectively temp 1-3 at a certain target temperature.
93 See below for the description of the sysfs-interface.
98 corresponding beep bit to be on for a triggered alarm to sound a beep.
105 `*_beep` files as described in `Documentation/hwmon/sysfs-interface.rst`.
110 (again following the pattern described in sysfs-interface).
114 the other. If you use the legacy bitmask method, your user-space code is
118 NOTE: All new code should be written to use the newer sysfs-interface
126 ----------
127 The sysfs-interface is documented in the 'sysfs-interface' file. Only
128 chip-specific options are documented here.
131 pwm[1-3]_enable this file controls mode of fan/temperature control for
132 fan 1-3. Fan/PWM 4-5 only support manual mode.
136 * 3 Fan Speed Cruise mode (no further support)
138 temp[1-3]_target defines the target temperature for Thermal Cruise mode.
142 temp[1-3]_tolerance temperature tolerance for Thermal Cruise mode.
150 -----------------------------------
162 in5 (-12VIN) 0x000200 0x000200
163 in6 (-5VIN) 0x000400 0x000400
179 global_enable - 0x800000 (modified via beep_enable)