Lines Matching +full:input +full:- +full:only

10     Addresses scanned: -
18 Addresses scanned: -
26 Addresses scanned: -
34 Addresses scanned: -
42 Addresses scanned: -
50 Addresses scanned: -
57 Guenter Roeck <linux@roeck-us.net>
61 -----------
63 Chips in this series are multi-phase step-down converters with one or two
68 -----------
77 # echo tps53681 0x60 > /sys/bus/i2c/devices/i2c-1/new_device
81 ----------------
86 in1_input Measured input voltage.
88 in1_lcrit Critical minimum input voltage
90 TPS53679, TPS53681, TPS53688 only.
92 in1_lcrit_alarm Input voltage critical low alarm.
94 TPS53679, TPS53681, TPS53688 only.
96 in1_crit Critical maximum input voltage.
98 in1_crit_alarm Input voltage critical high alarm.
100 in[N]_label "vout[1-2]"
102 - TPS53647, TPS53667: N=2
103 - TPS53679, TPS53588: N=2,3
107 in[N]_lcrit Critical minimum input voltage.
109 TPS53679, TPS53681, TPS53688 only.
113 TPS53679, TPS53681, TPS53688 only.
117 TPS53647, TPS53667 only.
121 TPS53679, TPS53681, TPS53688 only.
125 TPS53679, TPS53681, TPS53688 only.
129 - TPS53647, TPS53667: N=1
130 - TPS53679, TPS53681, TPS53588: N=1,2
142 power1_input Measured input power.
144 power[N]_label "pout[1-2]".
146 - TPS53647, TPS53667: N=2
147 - TPS53676, TPS53679, TPS53681, TPS53588: N=2,3
153 curr1_input Measured input current.
155 curr1_max Maximum input current.
157 curr1_max_alarm Input current high alarm.
159 curr1_crit Critical input current.
161 curr1_crit_alarm Input current critical alarm.
163 curr[N]_label "iout[1-2]" or "iout1.[0-5]".
166 digit is the phase within the channel. Per-phase
167 telemetry supported on TPS53676 and TPS53681 only.
169 - TPS53647, TPS53667: N=2
170 - TPS53679, TPS53588: N=2,3
171 - TPS53676: N=2-8
172 - TPS53681: N=2-9
184 Limit and alarm attributes are only available for
185 non-phase telemetry (iout1, iout2).