Lines Matching +full:high +full:- +full:current

12     Addresses scanned: -
23 Addresses scanned: -
27 https://www.onsemi.com/pub_link/Collateral/ADP4000-D.PDF
29 https://www.onsemi.com/pub_link/Collateral/NCP4200-D.PDF
31 https://www.onsemi.com/pub_link/Collateral/JUNE%202009-%20REV.%200.PDF
37 Addresses scanned: -
55 Addresses scanned: -
73 Addresses scanned: -
83 Addresses scanned: -
88 Author: Guenter Roeck <linux@roeck-us.net>
92 -----------
95 It supports voltage, current, power, and temperature sensors as supported
98 Each monitored channel has its own high and low limits, plus a critical
105 -----------
116 $ echo ltc2978 0x60 > /sys/bus/i2c/devices/i2c-1/new_device
120 ---------------------
182 -------------
190 The following attributes are supported. Limits are read-write; all other
191 attributes are read-only.
204 inX_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
207 inX_crit_alarm Voltage critical high alarm.
215 currX_input Measured current. From READ_IIN or READ_IOUT register.
216 currX_max Maximum current.
218 currX_lcrit Critical minimum output current.
220 currX_crit Critical maximum current.
222 currX_alarm Current high alarm.
224 currX_max_alarm Current high alarm.
226 currX_lcrit_alarm Output current critical low alarm.
228 currX_crit_alarm Current critical high alarm.
233 currX_rated_max Maximum rated current.
242 powerX_alarm Power high alarm.
244 powerX_crit_alarm Output power critical high alarm.
258 tempX_crit Critical high temperature.
263 tempX_max_alarm Chip temperature high alarm. Set by comparing
269 tempX_crit_alarm Chip temperature critical high alarm. Set by comparing