Lines Matching +full:alert +full:- +full:celsius
10 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
26 Prefix: 'lm89' (no auto-detection)
58 Addresses scanned: I2C 0x4c - 0x4e
66 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
74 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
152 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
162 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
172 Addresses scanned: I2C 0x4c - 0x4d
182 Addresses scanned: I2C 0x4c - 0x4d
192 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
200 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
208 Addresses scanned: I2C 0x48-0x4f
212 http://datasheets.maxim-ic.com/en/ds/MAX6642.pdf
222 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3497
232 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3497
242 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3500
252 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3497
274 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
284 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
294 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/2578
306 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3370
318 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3370
328 http://www.maxim-ic.com/quick_view2.cfm/qv_pk/3500
338 http://www.maxim-ic.com/datasheet/index.mvp/id/4199
350 http://www.maxim-ic.com/datasheet/index.mvp/id/4199
410 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
418 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
426 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
434 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
442 Addresses scanned: I2C 0x18 - 0x1a, 0x29 - 0x2b, 0x4c - 0x4e
450 -----------
470 very similar. For reference, here comes a non-exhaustive list of specific
494 * Filter and alert configuration register at 0xBF.
495 * ALERT is triggered by temperatures over critical limits.
506 * Consecutive alert register at 0x22.
509 * ALERT is triggered by open remote sensor.
567 * The G variant is lead-free, otherwise similar to the W.
568 * Filter and alert configuration register at 0xBF
579 All temperature values are given in degrees Celsius. Resolution
586 values. To make life easier to user-space applications, two absolute values
588 Only the local hysteresis can be set from user-space, and the same delta
595 SMBus Alert Support
596 -------------------
598 This driver has basic support for SMBus alert. When an alert is received,
602 Semiconductor chips (NCT1008) do not implement the SMBus alert protocol
603 properly so additional care is needed: the ALERT output is disabled when
604 an alert is received, and is re-enabled only when the alarm is gone.
609 -----------