Lines Matching +full:chip +full:- +full:temperature +full:- +full:threshold +full:- +full:celsius
5 Contact: linux-pm@vger.kernel.org
14 Contact: linux-pm@vger.kernel.org
23 Contact: linux-pm@vger.kernel.org
32 Contact: linux-pm@vger.kernel.org
43 Contact: linux-pm@vger.kernel.org
66 Contact: linux-pm@vger.kernel.org
81 Contact: linux-pm@vger.kernel.org
94 read-only reporting, unless the 'online' state of the supply
106 Contact: linux-pm@vger.kernel.org
110 Reports the current TBAT battery temperature reading.
114 Reports the current supply temperature reading. This would
115 normally be the internal temperature of the device itself
116 (e.g TJUNC temperature of an IC)
120 Valid values: Represented in 1/10 Degrees Celsius
124 Contact: linux-pm@vger.kernel.org
128 Maximum TBAT temperature trip-wire value where the supply will
129 notify user-space of the event.
133 Maximum supply temperature trip-wire value where the supply
134 will notify user-space of the event.
137 user-space needs to know if the temperature has crossed an
138 upper threshold so it can take appropriate action (e.g. warning
139 user that the temperature is critically high, and charging has
144 Valid values: Represented in 1/10 Degrees Celsius
148 Contact: linux-pm@vger.kernel.org
153 Minimum TBAT temperature trip-wire value where the supply will
154 notify user-space of the event.
158 Minimum supply temperature trip-wire value where the supply
159 will notify user-space of the event.
161 This is normally used for the charging scenario where user-space
162 needs to know if the temperature has crossed a lower threshold
164 temperature level is high, and charging current has been
169 Valid values: Represented in 1/10 Degrees Celsius
173 Contact: linux-pm@vger.kernel.org
177 Reports the maximum allowed TBAT battery temperature for
182 Reports the maximum allowed supply temperature for operation.
186 Valid values: Represented in 1/10 Degrees Celsius
190 Contact: linux-pm@vger.kernel.org
194 Reports the minimum allowed TBAT battery temperature for
199 Reports the minimum allowed supply temperature for operation.
203 Valid values: Represented in 1/10 Degrees Celsius
207 Contact: linux-pm@vger.kernel.org
224 Contact: linux-pm@vger.kernel.org
241 Contact: linux-pm@vger.kernel.org
253 read-only reporting, unless the 'online' state of the supply
265 Contact: linux-pm@vger.kernel.org
271 Valid values: 0 - 100 (percent)
275 Contact: linux-pm@vger.kernel.org
277 Maximum battery capacity trip-wire value where the supply will
278 notify user-space of the event. This is normally used for the
279 battery discharging scenario where user-space needs to know the
286 Valid values: 0 - 100 (percent)
290 Contact: linux-pm@vger.kernel.org
292 Minimum battery capacity trip-wire value where the supply will
293 notify user-space of the event. This is normally used for the
294 battery discharging scenario where user-space needs to know the
301 Valid values: 0 - 100 (percent)
305 Contact: linux-pm@vger.kernel.org
310 Values close to 0% will be returned after (re-)calibration
317 Valid values: 0 - 100 (percent)
321 Contact: linux-pm@vger.kernel.org
333 Contact: linux-pm@vger.kernel.org
344 Contact: linux-pm@vger.kernel.org
354 Contact: linux-pm@vger.kernel.org
360 Valid values: 0 - 100 (percent)
364 Contact: linux-pm@vger.kernel.org
370 threshold set by the driver.
374 Valid values: 0 - 100 (percent)
378 Contact: linux-pm@vger.kernel.org
385 Quickly charge the battery using fast-charge
416 Contact: linux-pm@vger.kernel.org
427 Contact: linux-pm@vger.kernel.org
443 Contact: linux-pm@vger.kernel.org
445 Reports the charging current applied during pre-charging phase
454 Contact: linux-pm@vger.kernel.org
470 Contact: linux-pm@vger.kernel.org
473 is read-only reporting although for some supplies this can be
484 Contact: linux-pm@vger.kernel.org
493 inhibit-charge: Do not charge while AC is attached
494 force-discharge: Force discharge while AC is attached
499 Contact: linux-pm@vger.kernel.org
506 "Unknown", "NiMH", "Li-ion", "Li-poly", "LiFe",
512 Contact: linux-pm@vger.kernel.org
524 Contact: linux-pm@vger.kernel.org
539 Contact: linux-pm@vger.kernel.org
554 Contact: linux-pm@vger.kernel.org
558 system-level knowledge or user input (e.g. This is part of the
561 temperature targets). Note that this feature should not be
572 Contact: linux-pm@vger.kernel.org
576 system-level knowledge or user input. Use preferably this
586 Contact: linux-pm@vger.kernel.org
590 between online states (e.g. Fixed -> Programmable for a PD_PPS
599 1: Online Fixed - Fixed Voltage Supply
600 2: Online Programmable - Programmable Voltage Supply
605 Contact: linux-pm@vger.kernel.org
608 the supply, for example it can show if USB-PD capable source
611 Access: For power-supplies which consume USB power such
613 the connected USB power source and is Read-Only.
615 For power-supplies which act as a USB power-source such as
624 What: /sys/class/power/ds2760-battery.*/charge_now
630 coloumb counter value inside the battery monitor chip. This
636 What: /sys/class/power/ds2760-battery.*/charge_full
645 What: /sys/class/power_supply/max14577-charger/device/fast_charge_timer
651 charger operates in fast-charge mode. When the timer expires
652 the device will terminate fast-charge mode (charging current
657 - 5, 6 or 7 (hours),
658 - 0: disabled.
660 What: /sys/class/power_supply/max77693-charger/device/fast_charge_timer
666 charger operates in fast-charge mode. When the timer expires
667 the device will terminate fast-charge mode (charging current
672 - 4 - 16 (hours), step by 2 (rounded down)
673 - 0: disabled.
675 What: /sys/class/power_supply/max77693-charger/device/top_off_threshold_current
680 This entry shows and sets the charging current threshold for
681 entering top-off charging mode. When charging current in fast
683 interrupt and start top-off charging mode.
687 - 100000 - 200000 (microamps), step by 25000 (rounded down)
688 - 200000 - 350000 (microamps), step by 50000 (rounded down)
689 - 0: disabled.
691 What: /sys/class/power_supply/max77693-charger/device/top_off_timer
697 charger operates in top-off charge mode. When the timer expires
698 the device will terminate top-off charge mode (charging current
703 - 0 - 70 (minutes), step by 10 (rounded down)
705 What: /sys/class/power_supply/bq24257-charger/ovp_voltage
710 This entry configures the overvoltage protection feature of bq24257-
717 - 6000000, 6500000, 7000000, 8000000, 9000000, 9500000, 10000000,
720 What: /sys/class/power_supply/bq24257-charger/in_dpm_voltage
726 bq24257-type charger devices. Once the supply drops to the configured
733 - 4200000, 4280000, 4360000, 4440000, 4520000, 4600000, 4680000,
736 What: /sys/class/power_supply/bq24257-charger/high_impedance_enable
741 This entry allows enabling the high-impedance mode of bq24257-type
748 - 1: enabled
749 - 0: disabled
751 What: /sys/class/power_supply/bq24257-charger/sysoff_enable
756 This entry allows enabling the sysoff mode of bq24257-type charger
764 - 1: enabled
765 - 0: disabled
769 Contact: linux-pm@vger.kernel.org
780 Contact: linux-pm@vger.kernel.org
786 Valid values: 1-12
790 Contact: linux-pm@vger.kernel.org
795 Valid values: 1-31