Lines Matching +full:critical +full:- +full:action

16 		The contents of the label are free-form.
40 Voltage critical min value.
47 take drastic action such as power down or reset. At the very
60 Voltage critical max value.
67 take drastic action such as power down or reset. At the very
135 this voltage channel is being used for, and user-space
137 user-space.
145 When disabled the sensor read will return -ENODATA.
147 - 1: Enable
148 - 0: Disable
156 - 1: Failed
157 - 0: Ok
262 Only makes sense if the chip supports closed-loop fan speed
272 this fan channel is being used for, and user-space doesn't.
273 In all other cases, the label is provided by user-space.
281 When disabled the sensor read will return -ENODATA.
283 - 1: Enable
284 - 0: Disable
292 - 1: Failed
293 - 0: Ok
311 - 0: no fan speed control (i.e. fan at full speed)
312 - 1: manual fan speed control enabled (using `pwmY`)
313 - 2+: automatic fan speed control enabled
322 - 0: DC mode (direct current)
323 - 1: PWM mode (pulse-width modulation)
352 Number of trip points is chip-dependent. Use this for chips
363 Number of trip points is chip-dependent. Use this for chips
376 - 1: CPU embedded diode
377 - 2: 3904 transistor
378 - 3: thermal diode
379 - 4: thermistor
380 - 5: AMD AMDSI
381 - 6: Intel PECI
397 - 0: OK
398 - 1: temperature has reached tempY_max
414 - 0: OK
415 - 1: temperature has reached tempY_min
450 Temperature critical max value, typically greater than
459 Critical high temperature alarm flag.
461 - 0: OK
462 - 1: temperature has reached tempY_crit
468 Temperature hysteresis value for critical limit.
473 from the critical value.
491 - 0: OK
492 - 1: temperature has reached tempY_emergency
509 Temperature critical min value, typically lower than
518 Temperature hysteresis value for critical min limit.
523 from the critical min value.
543 this temperature channel is being used for, and user-space
545 user-space.
581 When disabled the sensor read will return -ENODATA.
583 - 1: Enable
584 - 0: Disable
622 Current critical low value
630 Current critical high value.
682 When disabled the sensor read will return -ENODATA.
684 - 1: Enable
685 - 0: Disable
817 system should take action to reduce power use.
862 Critical maximum power.
865 system is expected take drastic action to reduce
878 -ENODATA.
880 - 1: Enable
881 - 0: Disable
914 -ENODATA.
916 - 1: Enable
917 - 0: Disable
925 - 0: OK
926 - 1: Humidity limit has been reached
935 -ENODATA.
937 - 1: Enable
938 - 0: Disable
946 - 1: Failed
947 - 0: Ok
955 Unit: milli-percent (per cent mille, pcm)
966 this humidity channel is being used for, and user-space
968 user-space.
976 Unit: milli-percent (per cent mille, pcm)
984 - 0: OK
985 - 1: Maximum humidity detected
993 Unit: milli-percent (per cent mille, pcm)
1004 Unit: milli-percent (per cent mille, pcm)
1012 - 0: OK
1013 - 1: Minimum humidity detected
1021 Unit: milli-percent (per cent mille, pcm)
1032 Unit: milli-percent (per cent mille, pcm)
1040 Unit: milli-percent (per cent mille, pcm)
1049 - 0: OK
1050 - 1: intrusion detected
1063 - 0: disable
1064 - 1: enable
1072 - 0, off, n: disable
1073 - 1, on, y: enable